CELO main catalog Page 108
Commercial customer offer**Top sellers from CELO Befestigungssysteme GmbH
ResiTHERM® Permissible tension load and pressure load ResiTHERM® 16 1) at 24°/40° 2) M16 anchor rod in 8.8 applied injection mortar ResiFIX VY SF acc. ETA10/0134 applied injection mortar ResiFIX VY SF acc. ETA-15/0320 Base material Concrete C20/25 3) Solid sand-lime brick KS KS28-2,0 3) Solid brick MZ 202,0 1) [kN] [k[kN] [k[kN] 4,57 2,00 2,29 [kN] [kN] Hollow sand-lime brick KSL 12-1,4 4) Hollow brick HLZ 12-1,25 4) Aerated concrete AAC 2 3) [[kN]] [kN] N] [[kN] kN] 1,65 1,11 0,71 [kN] N] [[kN] kN] Permissible tension load Nper Insulation thickness e 60-300 mm Permissible pressure load Pper Insulation thickness e [kN] [[kN]] 60 - 220 mm 5,14 2,00 2,29 1,65 1,11 0,71 221 - 300 mm 5,14 2,00 2,29 1,65 1,11 0,71 80 100 100 130 130 100 Min. anchorage depth hef /RDGVLQFOXGHWKHSDUWLDOVDIHW\IDFWRUVRIWKHPDWHULDOJLYHQLQWKH(7$DVZHOODVDSDUWLDOVDIHW\IDFWRUIRUWKHDFWLRQVRIƍ) 2) For other temperature ranges see ETA-assessment. 3) In full material the tension load resistance can be used also for the pressure load resistance. 4) ,QKROORZPDWHULDOVWKHSUHVVXUHORDGUHVLVWDQFHVSHFLͤHGLQWKH(7$FDQEHDSSOLHGLIWKHVHWWLQJGHSWKLVGHHSHQRXJKWRLQFOXGHPLQLPXPZHEVZLWKWKHLQMHFWLRQ mortar. If the setting depth is lower and does not include 4 webs, then the pressure load resistance must be reduced. 1) Permissible tension load and pressure load ResiTHERM® 12 1) at 24°/40° 2) M16 anchor rod in 8.8 applied injection mortar ResiFIX VY SF acc. ETA10/0134 applied injection mortar ResiFIX VY SF acc. ETA-15/0320 Base material Concrete C20/25 3) Solid sand-lime brick KS KS28-2,0 3) Solid brick MZ 202,0 1) [kN] [k[kN] [k[kN] 5,14 2,00 2,00 [kN] [kN] [kN] 5,14 2,00 2,00 Hollow sand-lime brick KSL 12-1,4 4) Hollow brick HLZ 12-1,25 4) Aerated concrete AAC 2 3) [[kN]] [kN] N] [[kN] kN] 1,65 1,11 0,71 [[kN]] [kN] N] [[kN] kN] 1,65 1,11 0,71 Permissible tension load Nper Insulation thickness e 60 - 220 mm Permissible pressure load Pper Insulation thickness e 60 - 120 mm 121 - 160 mm 5,14 2,00 2,00 1,65 1,11 0,71 161 - 220 mm 2,86 2,00 2,00 1,65 1,11 0,71 70 100 100 130 130 100 Min. anchorage depth hef /RDGVLQFOXGHWKHSDUWLDOVDIHW\IDFWRUVRIWKHPDWHULDOJLYHQLQWKH(7$DVZHOODVDSDUWLDOVDIHW\IDFWRUIRUWKHDFWLRQVRIƍ) 2) For other temperature ranges see ETA-assessment. 3) In full material the tension load resistance can be used also for the pressure load resistance. 4) ,QKROORZPDWHULDOVWKHSUHVVXUHORDGUHVLVWDQFHVSHFLͤHGLQWKH(7$FDQEHDSSOLHGLIWKHVHWWLQJGHSWKLVGHHSHQRXJKWRLQFOXGHPLQLPXPZHEVZLWKWKHLQMHFWLRQ mortar. If the setting depth is lower and does not include 4 webs, then the pressure load resistance must be reduced. 1) 107
316 Pages | Valid until 03/2023 | Previous page | Next page
Choose your language
Legal issues
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.