fischer installation-systems main-catalogue Page 467
Commercial customer offer**Top sellers from Fischer
fischer Catalogue Installation Systems FUS-Channel / FCA-Cantilever arm Load table based on the Adivisory Opinion No. GS 3.2/14-175-4 The following figures are valid for FUS channels and FCA cantilever arms, galvanized, hdg and stainless steel. FUS/FCA 41/2,5 (Picture 1–3) MLAR loads Threaded rods ≥ 4.8 strain F-resistance Max. strain ls min a 1) 30 min a 2) 30 60 90 120 [mm] [mm] [kN] [mm] [kN] [kN] [kN] [kN] Load case Point load Multiple load 3) Uniformly distributed load Max. Loads Fire resistance time [minute] ≤ 400 ≤ 50 0,90 278 2,40 1,33 0,92 0,72 ≤ 700 ≤ 50 – 320 1,61 1,04 0,80 0,67 ≤ 400 ≤ 50 0,90 278 2,40 1,33 0,92 0,72 ≤ 700 ≤ 50 – 320 1,61 1,04 0,80 0,67 ≤ 400 ≤ 50 1,50 258 3,00 2,10 1,41 1,06 ≤ 700 ≤ 50 0,60 299 2,44 1,57 1,21 1,00 ≤ 50 – 468 3,29 1,81 1,27 0,98 ≤ 1250 FUS/FCA 62/2,5 (Picture 1–3) MLAR loads Threaded rods ≥ 4.8 strain F-resistance Min. Max. strain ls min a 1) 30 min a 2) 30 60 90 120 [mm] [mm] [kN] [mm] [kN] [kN] [kN] [kN] Load case Point load Multiple load 3) Uniformly distributed load Max. Loads Fire resistance time [minute] ≤ 400 ≤ 50 1,76 25 1,76 1,06 0,78 0,62 ≤ 1000 ≤ 50 – 460 2,27 1,31 0,93 0,72 0,62 ≤ 400 ≤ 50 1,76 25 1,76 1,06 0,78 ≤ 960 4) ≤ 50 4,30 550 4,30 2,14 1,39 1,01 ≤ 1000 ≤ 50 0,55 661 2,52 1,60 1,21 0,99 0,62 ≤ 400 ≤ 50 1,76 25 1,76 1,06 0,78 ≤ 960 4) ≤ 50 4,30 550 4,30 2,14 1,39 1,01 ≤ 1000 ≤ 50 0,55 661 2,52 1,60 1,21 0,99 ≤ 50 0,50 592 2,41 1,65 1,31 1,11 ≤ 1250 FUS 62/2,5 (Picture 4) MLAR loads Vertical FUS 41/2,5 Max. Loads strain F-resistance Max. strain ls min a 1) 30 min a 2) 30 60 90 120 [mm] [mm] [kN] [mm] [kN] [kN] [kN] [kN] Point load ≤ 1000 ≤ 50 0,57 369 1,33 0,87 0,68 0,57 Multiple load 3) ≤ 1000 ≤ 50 0,62 649 1,92 1,34 1,08 0,92 ≤ 1000 ≤ 50 0,62 649 1,92 1,34 1,08 0,92 Load case Fire resistance time [minute] 10 1) Valid for a suspension height ha ³ 500 mm 2) Based on suspension height ha = 250mm, Expansion length of threaded rods in case of fire ~ 10mm/m 3) Given load values apply for multiple loads as summated point loads symmetrical allocated 4) This values are valid for FCA 62/2,5 with additional support by threaded rod FLS-Channel / ALK-Cantilever arm Load table based on the Adivisory Opinion No. GS 3.2/15-141-4 The following figures are valid for FLS channels and ALK cantilever arms, galvanized, hdg and stainless steel. FLS/ALK 37/1,2 (Picture 1-3) MLAR loads strain Threaded rods ≥ 4.8 Load case Point load Multiple load 3) Uniformly distributed load Max. Loads F-resistance Min. Max. strain Fire resistance time [minute] ls min a 30 min a 30 60 90 120 [mm] [mm] [kN] [mm] [kN] [kN] [kN] [kN] 0,09 ≤ 400 1) ≤ 50 0,24 93 0,24 0,13 0,10 ≤ 400 2) ≤ 50 0,09 289 0,47 0,38 0,33 0,30 ≤ 400 4) ≤ 50 0,32 226 1,33 0,78 0,53 0,40 ≤ 400 1) ≤ 50 0,72 93 0,72 0,38 0,30 0,27 ≤ 400 2) ≤ 50 0,26 289 1,42 1,13 0,99 0,90 ≤ 400 4) ≤ 50 0,81 226 1,33 0,78 0,53 0,40 ≤ 400 1) ≤ 50 0,72 93 0,72 0,38 0,30 0,27 ≤ 400 2) ≤ 50 0,35 308 1,37 1,19 1,06 0,95 ≤ 400 4) ≤ 50 0,81 226 1,33 0,78 0,53 0,40 1) Valid for a suspension height ha = 0 mm, s. picture 2 2) Valid for a suspension height ha = 500 mm, s. picture 1 (Expansion length of threaded rods in case of fire ~ 10 mm/m) 3) Given load values apply for multiple loads as summated point loads symmetrical allocated 4) This values are valid for ALK 37–450 with additional support by threaded rod, s picture 3 (ha = 500 mm) 467
500 Pages | Valid until 12/2025 | Previous page | Next page
Choose your language
Legal issues
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.
