fischer installation-systems main-catalogue Page 464
Commercial customer offer**Top sellers from Fischer
fischer Catalogue Installation Systems Fire protection. Fire protection in pipe installations according to the latest standards · Fire-proof installations for individual pipes and pipe routes from R30 - R120 or F30 to F120. · Proof of compliance with the criteria of MLAR (German standard pipe system directive) for installation in escape and rescue routes Permissible deformation of mounting rails or pipe clamps, for example, was determined. The necessity for these considerations arises from the properties of the steel, which at 30 minutes is subjected to a temperature of >800 °C according to the standard temperature curve (ISO curve). Reduction factors kθ 1,0 Fire protection - protection goals Firstly, fire protection serves to protect people, and is regulated by the building laws in the respective countries (or regional states). Secondly, fire protection serves to protect property and this is regulated by the insurance associations, such as VdS and FM. These requirements partially go beyond the building legislation. This is particularly evident in the installation of fire protection systems, such as sprinklers, etc., as approved or recognised components must be used here. (See the following section for further details on this) 10 0,9 Yield strength kγ,θ = fγ,θ / fγ 0,8 0,7 0,6 Elasticity module kΕ,θ = Εа,θ / Εа 0,5 0,4 0,3 0,2 Proportional limit kρ,θ = fρ,θ / fρ 0,1 0,0 0 200 400 600 800 1000 1200 Steel temperature[°C] Fire inspection reports for the mounting of pipe clamps and mounting rails Fire safety inspection reports meet the requirements for fire protection according to the building regulations of the countries and, especially for Germany, according to the nationwide homonymic German pipe systems directive (LAR), based on the standard pipe systems directive of 2005 (MLAR 2005). Personal protection is defined in the MLAR Directive through clear rules for escape routes, such as corridors, stairwells and hallways between stairwells and the exit. The key message is to ensure the safety of the escape route by ensuring the functioning of the fire-proof sub-ceiling. To this end, compliance with the minimum distance of min a ≤ 50 mm according to MLAR is required between installations and underlying suspended fire-proof F30 sub-ceilings (fire resistance of 30 minutes). Based on the fire inspections, load information for a fire resistance of 30 minutes in relation to the maximum 464 Dependency of the yield strength, proportional limit and elasticity module on the temperatutre (basis: EN1993-1-2:2012-12 Eurocode 3). Additionally, the same information is documented in the inspection reports for a fire resistance rating of R30, R60, R90 and R120 according to EN1363-1 and DIN4102-2. (see following load tables) Product overview with proof in inspection reports and supplementary sheets. Product Document no. MLAR R30 – R120 F30 – F120 FRS MFPA Leipzig - GS 3.2/14-175-2 ja ja FUS/ FCA MFPA Leipzig - GS 3.2/14-175-4 ja ja FRSLUniversal MFPA Leipzig - GS 3.2/18-120-2 ja ja FLS/ ALK MFPA Leipzig - GS 3.2/15-141-4 ja ja SB MPA-NRW – 210005109-7 SBS MPA-NRW – 210005109-4 ja ja PDH-K MPA-NRW – 210005109-6 ja ja ja
500 Pages | Valid until 12/2025 | Previous page | Next page
Choose your language
Legal issues
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.
