REMKO Complete Catalog Page 101
Commercial customer offer**Top sellers from Remko
Sample calculation Parameters ■ Cooling capacity 40 kW ■ Pipeline length 20 m ■ Copper piping used ■ Anti-freeze protection to -20°C (34% ethylene glycol) Solution Values taken from table Copper pipe Ø 54 mm Pressure loss ∆P 240 Pa/m Pressure loss per partial section 240 Pa/m x 20 m = 4800 Pa = 4,8 kPa Feed and return lines 4,8 kPa x 2 = 9,6 kPa Insulation thickness Values taken from table = 14,5 mm Glycol requirement 0,65 L/m x 20 m x 2 = 26,0 L 99
436 Pages | Valid until 12/2026 | Previous page | Next page
Choose your language
Legal issues
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.