Rothoblaas - X-RAD Seite 50
Gewerbekunden Angebot**Topseller von RothoBlaas Deutschland
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
zzgl. Versand
X-ONE X-PLATE X-SEAL STRUCTURAL ENGINEERING The aim of this section is to provide the resistance specifications for X-PLATE connection plates. The plates, of varying thickness according to the type, are all made of S355JR steel, CE marked according to EN1090 in EXC2 execution class. Each plate has been designed and verified by applying the maximum stresses transmitted by the X-ONE connector, according to three classes of strengths (1): 1. OVERALL STRENGTHS OF THE PLATE (with FEM analysis): shear; pure traction; pure compression; buckling stress or flexural stress. 2. LOCAL STRENGTHS: shear strength of the bolt (EN 1993-1-8 §3.6.1); bearing strength of the plate (EN 1993-1-8 §3.6.1); block tearing strength of the plate (EN 1993-1-8 §8.10.2); strength of the welds. 3. FASTENING STRENGTH ON THE FOUNDATION SUPPORT X-PLATE BASE PLATES The XPLATE BASE plates can be used under the following conditions: use of vinyl ester chemical anchor and 20 mm diameter threaded rod - steel strength grade 8.8 minimum strength class for C25/30 concrete X-PLATE BMINI and BMAXI plates fully restore the resistance of the X-ONE connector. X-PLATE BMINIL/R and BMAXIL/R plates partially restore the resistance of the X-ONE connector. This aspect is illustrated by the resistance domains shown below (2). RESISTANCE DOMAINS OF X-PLATE PLATES COMPARED TO THE RESISTANCE DOMAIN OF THE X-ONE CONNECTOR -250 -200 -150 -100 -50 -325 -275 -225 -175 -125 -75 -25 0 25 75 125 175 225 275 325 50 100 150 200 250 300 X-ONE X-PLATE BMINI local strengths X-PLATE BMINI overall strengths X-PLATE BMINI foundation fastening strength (uncracked concrete hef = 200) X-PLATE BMINI foundation fastening strength (cracked concrete hef = 200) X-PLATE BMINI - Design resistance domain NOTE: (1) The full report on structural design of the X-PLATE plates can be downloaded from www.rothoblaas.com or from the MyProject software. (2) The domains are shown according to the reference system for the X-ONE connector. To refer to the reference system for the X-PLATE plates, by applying forces on the X-PLATE plates that are equal and opposite to those applied on the X-ONE connector, these domains must be mirrored with respect to the bisector of the first quadrant. 48 X-PLATE
84 Seiten | Gültig bis 04/2024 | Vorherige Seite | Nächste Seite
Sprache wählen
Rechtliches
Ausschließlich verantwortlich für Inhalt, Preis- und Artikelangaben der dargestellten Produkte und Angebote innerhalb der Kataloge ist der Hersteller. Technische und optische Änderungen des Herstellers und Irrtümer vorbehalten.
Anfrageformular für spezielle Produkte
Der ToolTeam® Beschaffungsservice
Sie suchen Produkte die im Katalog abgebildet, aber online nicht direkt kaufbar sind?Unser Beschaffungs-Service macht Ihnen gerne ein unverbindliches und individuelles Angebot.
