ELMAG Discount News Seite 37

Gewerbekunden Angebot**
Seite 36ELMAG Discount News Seite 37
Produkte anzeigen
search
keyboard_arrow_up
/ 308

Produkte der Katalogseite

keyboard_arrow_down
  • 230 V / 50 Hz (2)
keyboard_arrow_down
  • 50cm (1)
  • 59cm (1)
keyboard_arrow_down
  • 6.500l/min (1)
  • 600l/min (1)
keyboard_arrow_down
  • 45cm (1)
  • 90cm (1)
-8% ELMAG ELMAG MARK-Kältetrockner 11527
11527
Angebot anfragen
3.992,45 € UVP
9 Varianten
-8% ELMAG ELMAG MARK-Kältetrockner 11519
11519
Angebot anfragen
1.416,10 € UVP
5 Varianten
-8% ELMAG ELMAG Wandkonsole mit Wanne (galv. Verzinkt) 11532
11532
214,60 €
zzgl. Versand
233,25 € UVP
-8% ELMAG ELMAG Bypass 1/2’ für MDX 400-1800 11534
11534
422,15 €
zzgl. Versand
458,15 € UVP
-7% ELMAG ELMAG Filter-Anschluss-Set für MDX 400-1800 12290
12290
199,39 €
zzgl. Versand
214,20 € UVP
2 Varianten
Alle Produkte von ELMAG anzeigen
1 2 3 Compressor with aftercooler Pre-filter "G" or centrifugal separator "WS" Fine filter "C" 2 4 5 Environmentally friendly refrigerant gases Activated charcoal filter "V" Refrigeration dryer MDX 3 2 1 3 4 1 5 5 High-quality compressed air with lower dew point (air purity according to ISO 8573-1: Class 1:4:2) High-quality compressed air with lower dew point and lower oil concentration (air purity according to ISO 8573-1: Class 1:4:1) Available options (for MDX 400-1800, filters are not included): Bypass valve and filter holder 1/2“ (Order no. 11534): The optional bypass function allows the system to use the filters only during maintenance or in the event of a malfunction of the dryer, so that downtimes are avoided. Filter Holder 1/2“ (Order No. 12290): With this option, two filters can be installed on the back of the dryer, which the overall dimensions and installation costs are reduced. Wall mounted console with tub for MDX 400-1800 (Order No. 11532) Effective Operating delivery rate pressure max. Electric motor l/min Refrigeration dryer MDX 400 350 Refrigeration dryer MDX 600 600 Refrigeration dryer MDX 900 850 Refrigeration dryer MDX 1200 1.200 Nominal power Voltage/ frequency Watts V/Hz bar 16 Dimensions l b h Desired. Order number inch cm cm cm kg Automatic condensate drainage Models Air input/ output 130 1/2 AG 35 50 45 19  11518 164 1/2 AG 35 50 45 19  11519 190 1/2 AG 35 50 45 20  11520 266 1/2 AG 35 50 45 25  11521 11522 Refrigeration dryer MDX 1800 1.825 284 1/2 AG 35 50 45 27  Refrigeration dryer MDX 2400 2.350 609 1 IG 37 50 76 44  11523 Refrigeration dryer MDX 3000 3.000 673 1 IG 37 50 76 44  11524 Refrigeration dryer MDX 3600 3.600 793 1 1/2 IG 46 56 79 53  11525 Refrigeration dryer MDX 4100 4.100 Refrigeration dryer MDX 5200 5.200 13 230/50 870 1 1/2 IG 46 56 79 60  11517 1.072 1 1/2 IG 46 56 79 65  11526 Refrigeration dryer MDX 6500 6.500 1.190 1 1/2 IG 58 59 90 80  11527 Refrigeration dryer MDX 7700 7.700 1.446 1 1/2 IG 58 59 90 80  11528 Refrigeration dryer MDX 10000 10.000 1.319 2 IG 74 90 97 128  11529 Refrigeration dryer MDX 12000 12.000 1.631 2 IG 74 90 97 146  11530 400/50 NOTE: LIMITATIONS: Reference conditions: - Operating pressure: 7 bars - Operating temperature: 35°C - Temperature: 25°C - Pressure dew point: +3 °C +/- 1 - Operating pressure: 16 bar - MDX 400-1800 13 bar - MDX 2400-12000 - operating temperature: 55 °C - Min./max. Room temperature: +5 °C; 45°C Determination of the delivery rate under different operating conditions Correction factor: °C Room temperature A 25 30 35 40 45 1.00 0.92 0.84 0.80 0.74 MDX 400-7700 1.00 0.91 0.81 0.72 0.62 from MDX 10000 Operating temperature °C 30 B 1.24 1.00 0.82 0.69 0.58 0.45 MDX 400-12000 Operating pressure bar C 5 35 6 40 7 45 8 50 9 55 10 11 12 13 14 15 16 0.90 0.96 1.00 1.03 1.06 1.08 1.10 1.12 1.13 1.15 1.16 1.17 MDX 400-12000 * = ELMAG special program The effective delivery rate applies only to those operating conditions in the tables of highlighted in red. In case of deviating conditions, the delivery rate must be determined as follows: • Select correction values for ambient temperature A, air intake temperature B and operating pressure (C) • Calculate the sum, i.e. A x B x C = correction coefficient • Multiply the effective delivery rate by the correction coefficient. The result corresponds to the effective delivery rate under changed operating conditions. 37 COMPRESSED AIR TECHNOLOGY Typical applications:

308 Seiten | Gültig bis 12/2025 | |

PDF Download (46MB)
Seite als PDF speichern
Angebot anfragen
(unverbindlich)

Sprache wählen

Rechtliches

Das Angebot richtet sich ausschließlich an Geschäftskunden, Unternehmen, öffentliche Einrichtungen, Gewerbetreibende und Freiberufler. Alle Preise in Katalogen verstehen sich zzgl. MwSt., ggf. zzgl. Versandkosten und Aufschlägen.
Ausschließlich verantwortlich für Inhalt, Preis- und Artikelangaben der dargestellten Produkte und Angebote innerhalb der Kataloge ist der Hersteller. Technische und optische Änderungen des Herstellers und Irrtümer vorbehalten.

Anfrageformular für spezielle Produkte

Personal-Quote Personal-Quote

Der ToolTeam® Beschaffungsservice

Sie suchen Produkte die im Katalog abgebildet, aber online nicht direkt kaufbar sind?
Unser Beschaffungs-Service macht Ihnen gerne ein unverbindliches und individuelles Angebot.


Bitte füllen Sie alle Pflichtfelder (rot unterstrichen)
keyboard_arrow_down
Bitte füllen Sie alle Pflichtfelder (rot unterstrichen)