as - Schwabe main catalogue Seite 129
Gewerbekunden Angebot**
Produkte anzeigen
Topseller von as - Schwabe
60382
23,10 €
zzgl. Versand
zzgl. Versand
12279
22,20 €
zzgl. Versand
zzgl. Versand
11462
24,10 €
zzgl. Versand
zzgl. Versand
46978
77,10 €
zzgl. Versand
zzgl. Versand
11432
21,89 €
zzgl. Versand
zzgl. Versand
70800
20,65 €
zzgl. Versand
zzgl. Versand
61475
24,95 €
zzgl. Versand
zzgl. Versand
60495
20,50 €
zzgl. Versand
zzgl. Versand
12706
24,95 €
zzgl. Versand
zzgl. Versand
(2,50 € / Meter)
12110
24,79 €
zzgl. Versand
zzgl. Versand
11461
24,10 €
zzgl. Versand
zzgl. Versand
60437
23,70 €
zzgl. Versand
zzgl. Versand
24033
20,25 €
zzgl. Versand
zzgl. Versand
47250
22,20 €
zzgl. Versand
zzgl. Versand
60494
21,69 €
zzgl. Versand
zzgl. Versand
51011
23,75 €
zzgl. Versand
zzgl. Versand
61489
20,80 €
zzgl. Versand
zzgl. Versand
51013
23,05 €
zzgl. Versand
zzgl. Versand
59105
21,20 €
zzgl. Versand
zzgl. Versand
60210
25,65 €
zzgl. Versand
zzgl. Versand
60310
25,35 €
zzgl. Versand
zzgl. Versand
70802
20,65 €
zzgl. Versand
zzgl. Versand
70977
23,35 €
zzgl. Versand
zzgl. Versand
11431
21,89 €
zzgl. Versand
zzgl. Versand
62463
16,30 €
zzgl. Versand
zzgl. Versand
62453
15,79 €
zzgl. Versand
zzgl. Versand
60484
18,80 €
zzgl. Versand
zzgl. Versand
11672
16,85 €
zzgl. Versand
zzgl. Versand
11671
16,85 €
zzgl. Versand
zzgl. Versand
12711
15,75 €
zzgl. Versand
zzgl. Versand
(0,79 € / Meter)
60463
14,85 €
zzgl. Versand
zzgl. Versand
60488
15,79 €
zzgl. Versand
zzgl. Versand
60600
16,49 €
zzgl. Versand
zzgl. Versand
61492
18,90 €
zzgl. Versand
zzgl. Versand
Alle Produkte von as - Schwabe anzeigen
RCD ≈ Residual Current Device What are residual current devices used for? A residual current device provides protection against unacceptably high touch currents. They are designed to protect people from electrical accidents and also to prevent the risk of fire. How does an RCD work? An RCD disconnects the monitored circuit from the rest of the network when a certain residual current is exceeded. Residual currents occur, for example, when a fault current flows through the human body or via defective insulation. The RCD compares the level of the outgoing current with that of the returning current. In an intact system, the sum of all currents flowing through the RCD must be zero. If this is not the case, the RCD intervenes. What is the correct term for it? In the EU, the English term RCD (Residual Current Protective Device) is well established. In general German usage, the terms “FI-Schutzschalter” or “FI-Schalter” for short are also commonly used (F = fault, I = formula symbol for electric current). Is RCD protection mandatory? In Germany, an RCD with a rated residual current of max. 30 mA is mandatory for all circuits that have socket outlets and whose rated current does not exceed 16 A. On construction sites, additional protection must be provided for all socket circuits with a rated current of up to 32 A and on agricultural and horticultural premises, regardless of their rated current. What standards apply on construction sites? Electrical operating materials used on commercial construction sites is subject to the DIN VDE 0100 standard. The German Employer’s Liability Insurance Association for the Construction Industry (Berufsgenossenschaft BAU) has regulated in detail what operating materials must be protected in which way in order to ensure the highest possible protection for the user. Part 0100-704 specifies the “Requirements for special types of premises, rooms and installations - construction sites”. RCD types RCDs are differentiated in terms of their suitability for detecting different types of residual currents. Type A RCDs are residual current devices that are independent of mains voltage and only respond to sinusoidal AC residual currents and pulsating DC residual currents. They must not be connected upstream in circuits with electronic operating materials, as this may impair their function. Type B RCDs must be installed for this application, as they also protect against smooth DC fault currents or higher frequency harmonic currents. Type A Type B sensitive to alternating and/or pulsating current all-current-sensitive Sinusoidal alternating currents Sinusoidal alternating currents pulsating direct currents Pulsating direct currents Smooth directcurrents 126
276 Seiten | Gültig bis 12/2023 | Vorherige Seite | Nächste Seite
Sprache wählen
Rechtliches
Das Angebot richtet sich ausschließlich an Geschäftskunden, Unternehmen, öffentliche Einrichtungen, Gewerbetreibende und Freiberufler. Alle Preise in Katalogen verstehen sich zzgl. MwSt., ggf. zzgl. Versandkosten und Aufschlägen.
Ausschließlich verantwortlich für Inhalt, Preis- und Artikelangaben der dargestellten Produkte und Angebote innerhalb der Kataloge ist der Hersteller. Technische und optische Änderungen des Herstellers und Irrtümer vorbehalten.
Ausschließlich verantwortlich für Inhalt, Preis- und Artikelangaben der dargestellten Produkte und Angebote innerhalb der Kataloge ist der Hersteller. Technische und optische Änderungen des Herstellers und Irrtümer vorbehalten.
Anfrageformular für spezielle Produkte
Der ToolTeam® Beschaffungsservice
Sie suchen Produkte die im Katalog abgebildet, aber online nicht direkt kaufbar sind?Unser Beschaffungs-Service macht Ihnen gerne ein unverbindliches und individuelles Angebot.
Bitte füllen Sie alle Pflichtfelder (rot unterstrichen)
keyboard_arrow_down
Bitte füllen Sie alle Pflichtfelder (rot unterstrichen)
