-32% RothoBlaas Deutschland RothoBlaas AFBØJNINGSSKIVE I ALUMINIUM MED EN RULLE SINGLE
SINGLE
64,75 €
ekskl. forsendelsesomkostninger
95,55 € MSRP
2 Variants
Se alle RothoBlaas Deutschland produkter
STRUCTURAL VALUES | TIMBER-TO-TIMBER | Fax | Fv | Fup | Flat UVT60215 total fastening + partial fastening 45° screws 90° screws LBS Ø5 x 50 LBS Ø5 x 60 LBS Ø5 x 70 45° screws VGS Ø6 x 100 VGS Ø6 x 160 VGS Ø6 x 100 VGS Ø6 x 160 [kN] [kN] [kN] [kN] Rax,k 2,9 2,9 2,9 2,9 Rv,k 37,3 62,8 18,7 31,4 Rup,k 4,7 7,9 4,7 7,9 Rlat,k 3,4 3,4 2,8 2,8 Rax,k 3,5 3,5 3,5 3,5 Rv,k 37,3 62,8 18,7 31,4 Rup,k 4,7 7,9 4,7 7,9 Rlat,k 3,5 3,5 2,9 2,9 Rax,k 4,2 4,2 4,2 4,2 Rv,k 37,3 62,8 18,7 31,4 Rup,k 4,7 7,9 4,7 7,9 Rlat,k 3,7 3,7 3,0 3,0 NOTES GENERAL PRINCIPLES (1) The minimum dimensions of the wooden elements vary when the stress • Characteristic values are consistent with EN 1995:2014 and in accordance with the product ETA� direction varies and must be checked on a time-by-time basis� The table shows the minimum dimensions in order to guide the designer in the choice of the connector� Dimensioning and verification of the timber elements must be carried out separately� (2) Partial fastening must be carried out according to the installation diagrams shown in the figure and in accordance with ETA� (3) In case of Fv or Fup stress, an additional inclined screw is required in the main beam to be inserted after installing the connector� • Design values can be obtained from characteristic values as follows: Rd = Rk kmod γM The coefficients kmod and γM should be taken according to the current regulations� • A timber density of ρk = 350 kg/m3 was considered for the calculation process� • Dimensioning and verification of the timber elements must be carried out separately� • The following verification shall be satisfied for combined loading: Fax,d Rax,d + Fv/up,d Rv/up,d 2 + Flat,d Rlat,d 2 ≥ 1 • Full fastening for beam applications or partial fastening for column applications is possible� On the secondary beam side, inclined screws must always be inserted in the upper two holes and the two lower holes� • Lateral stress Flat is assumed to act at a distance e = H/2 from the center of the connector� For different values of "e" it is possible to calculate the strength values according to ETA� • It is assumed that the main beam is prevented from rotating� If the UV T connector is installed on only one side of the beam, the main beam must be checked for a torque caused by eccentricity Mv = Fd � (BH /2 � 14 mm)� This applies in the case of connection on both sides of the main beam when the difference between the acting stresses is > 20%� JOINTS FOR BEAM | UV T | 65

580 Sider | Gyldig indtil 12/2026 | |

PDF Download (261MB)
Gem siden som PDF
Anmod om tilbud
(uforpligtende)

Juridiske oplysninger

Tilbuddet er udelukkende rettet mod erhvervskunder, virksomheder, offentlige institutioner, håndværkere og freelancere. Alle priser i kataloger er eksklusive moms, forsendelsesomkostninger og eventuelle tillæg.
Producenten er kun ansvarlig for indhold, pris og artikeldetaljer for produkterne og tilbuddene i katalogerne. Med forbehold for tekniske og optiske ændringer og fejl fra producentens side.

Anmodningsskema til specialprodukter

Personal-Quote Personal-Quote

ToolTeam® indkøbsservice

Leder du efter produkter, der er vist i kataloget, men ikke kan købes direkte online?
Vores indkøbstjeneste vil med glæde give dig et uforpligtende og individuelt tilbud.


Udfyld alle obligatoriske felter (understreget med rødt)
keyboard_arrow_down
Udfyld alle obligatoriske felter (understreget med rødt)