Rothoblaas - Plates and Connectors Side 358

Kommercielt kundetilbud **
Rothoblaas - Plates and Connectors Side 358Side 359
Vis produkter
search
keyboard_arrow_up
/ 580

Produkter fra katalogside

-33% RothoBlaas Deutschland RothoBlaas PROTECTOR EVO SIKKERHEDSHJELM
PRO
93,30 €
ekskl. forsendelsesomkostninger
139,25 € MSRP
13 Variants
Se alle RothoBlaas Deutschland produkter
STRUCTURAL VALUES | TIMBER-TO-CONCRETE | F2/3 STRENGTH ON TIMBER-TO-ALUMINIUM SIDE CLT profile ALUSTART80 ALUSTART100 ALUSTART120 ALUSTART175 pattern C/GL CONCRETE R2/3,k timber ey ez K2/3,ser [kN/m] [mm] [mm] [N/mm ∙ 1/m] total 112,4 - 12000 pattern 1 55,4 44,7 8000 pattern 2 36,4 29,4 4000 pattern 3 26,9 21,7 3000 total 112,4 - 12000 pattern 1 55,4 44,7 8000 pattern 2 36,4 29,4 4000 pattern 3 26,9 21,7 total 105,9 - pattern 1 52,2 42,1 8000 pattern 2 34,3 27,7 4000 pattern 3 25,3 20,4 3000 total 90,2 - 12000 29,5 80,5 F2 F3 3000 12000 pattern 1 44,4 35,8 8000 pattern 2 29,2 23,6 4000 pattern 3 21,6 17,4 3000 • C/GL: solid timber or glulam The installation of the ALUSTART35 extension, or the presence of a grout layer up to 30 mm with minimum class M10, do not affect the values in the table� CONCRETE STRENGTH total fastening partial fastening 5 anchors/m 2,5 anchors/m fastening holes Ø12 configuration on concrete uncracked cracked seismic type ØxL VIN-FIX 5�8 VIN-FIX 8�8 SKR AB1 VIN-FIX 5�8 VIN-FIX 8�8 HYB-FIX 8�8 SKR AB1 EPO-FIX 8�8 M12 x 140 M12 x 140 12 x 90 M12 x 100 M12 x 195 M12 x 195 M12 x 195 12 x 90 M12 x 100 M12 x 195 R2/3,d concrete [mm] [kN/m] 94,0 129,0 83,0 94,6 94,0 106,0 129,0 54,2 94,6 51,2 47,0 64,5 41,5 50,3 47,0 53 64,5 27,1 50,5 25,6 ANCHORS VERIFICATION FOR STRESS LOADING F2/3 Fastening to concrete using alternative anchors must be verified on the basis of the load acting on the anchors, which depend on the fastening configuration� In order to consider an anchor as a reagent it is necessary that the distance of the anchor from the profile edge is at least 50 mm� The anchor group must be verified for: F2/3 VEd,x,bolts = F2/3 MEd,z,bolts = F2/3,d x ey MEd,x,bolts = F2/3,d x ez ez z x In which F2/3,d represents the shear stress acting on the ALU START connector� The check is satisfied if the design shear strength of the anchor group is greater than the design stress: R2/3,d concrete ≥ F2/3,d� 358 | ALU START | SYSTEMS FOR WALLS, FLOORS AND BUILDINGS y ey ≥ 50

580 Sider | Gyldig indtil 12/2026 | |

PDF Download (261MB)
Gem siden som PDF
Anmod om tilbud
(uforpligtende)

Juridiske oplysninger

Tilbuddet er udelukkende rettet mod erhvervskunder, virksomheder, offentlige institutioner, håndværkere og freelancere. Alle priser i kataloger er eksklusive moms, forsendelsesomkostninger og eventuelle tillæg.
Producenten er kun ansvarlig for indhold, pris og artikeldetaljer for produkterne og tilbuddene i katalogerne. Med forbehold for tekniske og optiske ændringer og fejl fra producentens side.

Anmodningsskema til specialprodukter

Personal-Quote Personal-Quote

ToolTeam® indkøbsservice

Leder du efter produkter, der er vist i kataloget, men ikke kan købes direkte online?
Vores indkøbstjeneste vil med glæde give dig et uforpligtende og individuelt tilbud.


Udfyld alle obligatoriske felter (understreget med rødt)
keyboard_arrow_down
Udfyld alle obligatoriske felter (understreget med rødt)