Rothoblaas - Plates and Connectors Side 105

Kommercielt kundetilbud **
Side 104Rothoblaas - Plates and Connectors Side 105
Vis produkter
search
keyboard_arrow_up
/ 580

Produkter fra katalogside

-16% RothoBlaas Deutschland RothoBlaas STOPPUNKT MED STIGEKROG HOOKS
HOOKS
93,89 €
ekskl. forsendelsesomkostninger
111,25 € MSRP
9 Variants
-31% RothoBlaas Deutschland RothoBlaas HØREVÆRN - STØJREDUKTION 29DB HEAD
HEAD
26,95 €
ekskl. forsendelsesomkostninger
39,25 € MSRP
Se alle RothoBlaas Deutschland produkter
INSTALLATION | ALUMEGA JS MINIMUM DISTANCES AND DIMENSIONS STA smooth dowel Ø16 a3,t self-drilling dowel SBD Ø7,5 aS a3,t ≥ 37 mm a1 aS a4,t aS aS a2 ≥ 37 mm a4,t a2 H H aS hj H as a4,c hj ≥ H + 52 mm hj ≥ H a4,c bj Spacing between ALUMEGA JS side-by-side ≥ 37 mm meets the minimum spacing requirement of 10 mm between HV connectors on beam and column. If the JS connector is attached to an HP connector on beam and column, the minimum spacing between connectors is 49 mm. SBD Ø7,5 STA Ø16 dowel-dowel secondary beam-timber a1(1) [mm] ≥ 3∙d | ≥ 5∙d ≥ 23 | ≥ 38 - dowel-dowel a2 [mm] ≥ 3∙d ≥ 23 ≥ 48 dowel-beam end a3,t [mm] max (7 d; 80 mm) ≥ 80 ≥ 112 dowel-top of beam a4,t [mm] ≥ 4∙d ≥ 30 ≥ 64 dowel-bottom of beam a4,c [mm] ≥ 3∙d ≥ 23 ≥ 48 dowel-bracket edge as(2) [mm] ≥ 1,2∙d0(3) ≥ 10 ≥ 21 (1)Spacing between SBD dowels parallel to the fibre for load-to-grain angle α = 90° (F or F v up stress) and α = 0° (Fax stress) respectively. (2)It is advisable to pay special attention to the positioning of the SBD dowels with respect to the distance from the bracket edge, using a pilot hole if necessary. (3)Hole diameter. ASSEMBLY OF CONNECTORS OF DIFFERENT HEIGHTS ALUMEGA360HP column ALUMEGA240JV beam ALUMEGA240HP steel column ALUMEGA360JV A secondary beam connector (JV and JS) may be attached to a main element connector (HV and HP) of a different height. The configurations shown allow for balancing the strengths between the HP and JV connectors, and limit the extension of the inclined screws beyond the outline of the connectors (example on the left). The final strength is the minimum between the strength of the connectors and the bolts. beam PARTIAL FASTENING FOR HV AND JV CONNECTORS ALUMEGA360HV ALUMEGA360JV Partial fastening is permitted for the HV and JV connectors by omitting the first and last row of screws, respectively. This configuration is particularly favourable for beam-to-column connections, with the column extrados aligned with the beam extrados. column beam JOINTS FOR BEAM | ALUMEGA | 105

580 Sider | Gyldig indtil 12/2026 | |

PDF Download (261MB)
Gem siden som PDF
Anmod om tilbud
(uforpligtende)

Juridiske oplysninger

Tilbuddet er udelukkende rettet mod erhvervskunder, virksomheder, offentlige institutioner, håndværkere og freelancere. Alle priser i kataloger er eksklusive moms, forsendelsesomkostninger og eventuelle tillæg.
Producenten er kun ansvarlig for indhold, pris og artikeldetaljer for produkterne og tilbuddene i katalogerne. Med forbehold for tekniske og optiske ændringer og fejl fra producentens side.

Anmodningsskema til specialprodukter

Personal-Quote Personal-Quote

ToolTeam® indkøbsservice

Leder du efter produkter, der er vist i kataloget, men ikke kan købes direkte online?
Vores indkøbstjeneste vil med glæde give dig et uforpligtende og individuelt tilbud.


Udfyld alle obligatoriske felter (understreget med rødt)
keyboard_arrow_down
Udfyld alle obligatoriske felter (understreget med rødt)