Remko Stationary Hot Air Heating Systems Side 15
Kommercielt kundetilbud **Produkter fra katalogside
ekskl. forsendelsesomkostninger
ekskl. forsendelsesomkostninger
ekskl. forsendelsesomkostninger
ekskl. forsendelsesomkostninger
ekskl. forsendelsesomkostninger
ekskl. forsendelsesomkostninger
ekskl. forsendelsesomkostninger
ekskl. forsendelsesomkostninger
ekskl. forsendelsesomkostninger
LAS balanced flue system through the wall with burner fresh air supply Chimney duct through wall Type AW 1 Type AW 2 925 mm 750 mm 925 mm 750 mm D Installation height Min. 2.5 m Installation height Min. 2.5 m D Note Please observe the following pipe diameters during planning. Maximum additional pipe length1 GPC 20 GPC 40 GPC 60 GPC 80 AW1 Ø 80 AW1 Ø 100 AW2 Ø 80 AW2 Ø 100 AW1 Ø 802) 30+30 m 30+30 m 5+5 m - Ø connection 80 mm 100 mm 80 mm 100 mm AW1 Ø 1002) - - - 5+5 m Ø of wall opening 125 mm 150 mm 125 mm 150 mm AW2 Ø 80 30 m 30 m 15 m - AW2 Ø 100 - - - 30 m Plan a wall opening with 5 mm clearance After the determination of the chimney duct, the pressure loss for the respective unit must be established. When using chimney bends, the pressure losses must especially be taken into account. 2) Specification of the maximum fresh air and exhaust gas length. For GPS 60/80 in design AW1, longer variants are also available on request. 2) Exhaust gas duct, outside wall Unit type AW 1 Ø 80/100 2) LAS balanced flue system with integrated burner fresh air supply for exterior wall installation, including wind guard, 925 mm long AW 2 Ø 80/100 2) Exhaust gas pipe for exterior wall installation, including wind guard and protective grid for combustion air intake, 925 mm long Individual sections Exhaust gas or fresh air pipe Length 250 mm Exhaust gas or fresh air pipe Length 500 mm Exhaust gas or fresh air pipe Length 1000 mm Exhaust or fresh air bend 90° Exhaust or fresh air bend 45° Exhaust gas pipe with condensate drain Horizontal, length 185 mm, including adapter Ø 32 mm Protective grid For combustion air intake Connection ports With test nipple CE certificate no. CE 0432-BPR-119933 2) GPC 20 GPC 40 GPC 60 GPC 80 228774 228774 228774 228775 228772 228772 228772 228773 228868 228868 228868 228869 228871 228871 228871 228876 228872 228872 228872 228877 228910 228910 228910 229010 228909 228909 228909 229009 228956 228956 228956 229056 228960 228960 228960 229060 228981 228981 228981 229081 Exhaust gas system without test nipple 15
44 Sider | Gyldig indtil 12/2024 | Previous page | Næste side
Vælg dit sprog
Juridiske oplysninger
Producenten er kun ansvarlig for indhold, pris og artikeldetaljer for produkterne og tilbuddene i katalogerne. Med forbehold for tekniske og optiske ændringer og fejl fra producentens side.
Anmodningsskema til specialprodukter
ToolTeam® indkøbsservice
Leder du efter produkter, der er vist i kataloget, men ikke kan købes direkte online?Vores indkøbstjeneste vil med glæde give dig et uforpligtende og individuelt tilbud.
