TOX product catalogue Strana 190
Nabídka komerčních zákazníků **Nejlépe prodávané z TOX-DÜBEL
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
UD INCL ED ECI SP Installation system Thermo Proof Plus A L S E AL ANT Features Approved by the building authorities Variable M10 or M12 threaded rod connection The only approved spacer fastening with M10 threaded connection as used as standard, e.g. for French balconies Up to 250% more power than competitive products Suitable for insulation thicknesses and spacer installations up to 220/320 mm Aqua-Stop effectively protects against rotting of the facade due to moisture Safe protection against rust, energy loss and thermal bridges due to A4 stainless steel h1 hef TOX-Dübel-Technik GmbH TOX THERMO Proof Plus tETICS tfix Z-21.8-2020 d0 You Tube .com/toxgermany L = length of threaded rod www. Pack Item No. Content Thermo Proof Plus per pack 084 600 151 Insulation material 084 600 153 Thermo Proof Plus Large Pack Size / Content Driver mm 2x Iso Spacer - 2x threaded rod A4 M16x300 SW24 - 2x screw A4 M10x40 SW 2x screw A4 M12x40 SW 2x sieve sleeve 20 x 85 - 1x extension 10 x 200 - 1x Aqua-Stop 80 ml 80 ml 2x Iso Spacer - 2x threaded rod A4 M16x400 - 2x screw A4 M10x40 SW 2x screw A4 M12x40 SW 2x sieve sleeve 20x85 - 1x extension 10 x 250 - 1x Aqua-Stop 80ml 80 ml per pack SW24 mm 12x Iso Spacer - 12x threaded rod M16x300 SW24 - 12x sieve sleeve 20x85 - 8x Iso Spacer - 8x threaded rod M16x400 - 8x sieve sleeve 20x85 - 084 100 152 084 100 154 1 30 mm in plaster 190 2 The entire approval notice Z-21.8-2020 must be observed when sizing. SW24 Tightening torque Drill Ø Min. Drill hole depth Min. Anchoring depth Max. thickness Insulating layer Thickness Fixing Approval Nm d0 ø mm h1 ≥ mm hef ≥ mm tETICS ≤ mm tfix ≥ mm Dibt 20 (Concrete) 80 / 100 80 / 100 220 / 200 18 1⁾ (Concrete / (Concrete / (Concrete / (Concrete / solid solid solid solid masonry) masonry) masonry) masonry) min. 6 max. 28 min. 6 90 85 190 20 1⁾ (perforated (perforated (perforated (perforated max. 28 brick) brick) brick) brick) 20 (Concrete) 80 / 100 80 / 100 320 / 300 18 1⁾ (Concrete / (Concrete / (Concrete / (Concrete / solid solid solid solid masonry) masonry) masonry) masonry) min. 6 max. 28 min. 6 90 85 290 20 1⁾ (perforated (perforated (perforated (perforated max. 28 brick) brick) brick) brick) Nm d0 ø mm h1 ≥ mm hef ≥ mm tETICS ≤ mm tfix ≥ mm 20 (Concrete) 18 1⁾ (Concrete / solid masonry) 80 / 100 (Concrete / solid masonry) 80 / 100 (Concrete / solid masonry) 220 / 200 (Concrete / solid masonry) min. 6 max. 28 20 (Concrete) 20 1⁾ (perforated brick) 18 1⁾ (Concrete / solid masonry) 90 (perforated brick) 80 / 100 (Concrete / solid masonry) 85 (perforated brick) 80 / 100 (Concrete / solid masonry) 190 (perforated brick) 320 / 300 (Concrete / solid masonry) min. 6 max. 28 min. 6 max. 28 20 1⁾ (perforated brick) 90 (perforated brick) 85 (perforated brick) 290 (perforated brick) min. 6 max. 28 Dibt
216 Stránky | Platí do 12/2023 | Previous page | Další stránka
Vyberte si jazyk
Legální problémy
Výrobce je výhradně zodpovědný za obsah, cenu a detaily produktů a nabídek uvedených v katalozích. Technické a optické změny výrobce a chyby jsou vyhrazeny.
Formulář žádosti o speciální produkty
Služba nákupu ToolTeam®
Hledáte produkty, které jsou uvedeny v katalogu, ale nelze je zakoupit přímo online?Naše služba nákupu vám ráda zpracuje nezávaznou a individuální nabídku.
