TOX product catalogue Strana 149
Nabídka komerčních zákazníků **Nejlépe prodávané z TOX-DÜBEL
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Building materials & Holding values Apollo Concrete C 20/25 Solid brick MZ 12 Vertically perforated brick ≥ Hlz12 Bulk density 1 kg/dm³ Hollow brick ≥ Hbl2 Cellular concrete ≥ PB2, PP2 Gypsum plasterboard 12.5 mm 10 kg Gypsum plasterboard 2x12.5 mm 15 kg 6/50 20 kg 15 kg 20 kg 25 kg 10 kg 6/70 20 kg 15 kg 20 kg 25 kg 10 kg 10 kg 15 kg 8/60 50 kg 40 kg 25 kg 30 kg 15 kg 10 kg 15 kg 8/80 50 kg 40 kg 25 kg 30 kg 20 kg 10 kg 15 kg 8/100 50 kg 40 kg 25 kg 30 kg 20 kg 10 kg 15 kg 8/120 50 kg 40 kg 25 kg 30 kg 20 kg 10 kg 15 kg 8/140 50 kg 40 kg 25 kg 30 kg 20 kg 10 kg 15 kg 10/100 80 kg 60 kg 30 kg 35 kg 30 kg 10 kg 15 kg 10/120 80 kg 60 kg 30 kg 35 kg 30 kg 10 kg 15 kg 10/140 80 kg 60 kg 30 kg 35 kg 30 kg 10 kg 15 kg 10/160 80 kg 60 kg 30 kg 35 kg 30 kg 10 kg 15 kg The anchoring depth of the wall plug must be observed Drilling method and drill hole cleaning must be adapted to the building material The recommended loads only apply to installation in the building material, not for installation in joints Approved wall plugs must be used for fixings where safety is of importance (see also www.tox.de/safety+loads) Description & Area of Application 3-way split spreader element with metal tip Shaft with rotation locks Wall plug is completely pre-assembled with galvanized countersunk screw with TX driver Processing & Installation In cellular concrete P2 just hammer in without predrilling 1. Drilling Result in concrete 2. Clean drill hole Result in perforated brick 3. Drive in wall plugs Result in cellular concrete After setting the Apollo, be sure to tighten the screw – in aerated concrete, optimum holding values after 6 turns of the screw Holds in concrete and solid masonry through expansion Frames Drill into perforated brick and gypsum plasterboard without hammering in a rotary motion so that the webs in the perforated brick are not broken Holds in perforated brick by spreading and tying Holds behind gypsum plasterboard by tying In cellular concrete (aerated concrete), a deep-set rear gripping (tying) is created Through installation 4. Tighten screw 149
216 Stránky | Platí do 12/2023 | Previous page | Další stránka
Vyberte si jazyk
Legální problémy
Výrobce je výhradně zodpovědný za obsah, cenu a detaily produktů a nabídek uvedených v katalozích. Technické a optické změny výrobce a chyby jsou vyhrazeny.
Formulář žádosti o speciální produkty
Služba nákupu ToolTeam®
Hledáte produkty, které jsou uvedeny v katalogu, ale nelze je zakoupit přímo online?Naše služba nákupu vám ráda zpracuje nezávaznou a individuální nabídku.
