Pneumax - Hauptkatalog Strana 519
Nabídka komerčních zákazníků **Nejlépe prodávané z Pneumax GmbH
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Solenoid valves manifold Series 2500 "OPTYMA-T" 8 Input/Output Module General : Using the 2540.03.25P output terminal it is possible to make any electrical signals not used by valves available on a 25 sub-D female connector at the right end of the manifold. It is possible to then join a multi-core cable to link to the next manifold, or connect directly to one or two I/O modules. The I/O modules can accept input or output signals, depending upon what is connected. Ordering code 2540.08T 1 Air distributiOn Please note: If the manifold is connected by a multi-core connection, each connection can be used as either an input or an output, while if the manifold is connected to a serial node the connections can only be used as an output. It is possible to connect the manifold to up to two I/O modules. Each I/O module includes 8 diagnostic LEDs which indicate the presence of an Input / Output signal for each connector. Please note: For an LED to function, a signal of at least +15VDC must be present on pin 4 of the connector. If this signal is lower, the LED will not light, this does not compromise the normal Input / Output function of the unit. Overall dimensions and I/O layout : 72.7 67.7 DIAGNOSTIC GREEN LED VOLTAGE ON THROUGH-LINE 3 GREEN LED INPUT/OUTPUT 1 M8 CONNECTOR 3 POLES FEMALE PIN 1 4 3 4 DESCRIPTION +24 VDC INPUT/OUTPUT GND M8 CONNECTOR 3 POLES FEMALE Input features: Each connection can accept either two wire (switches, magnetic switches, pressure switches, etc.) or three wire connections (photocells, electronic end of stroke sensors, etc.) If +24VDC is required on at Pin 1 of each connector, it is possible to provide this via the through-line pin of the multi-pole connector. I.E : Pin 25 of the 25 pin multi-pole connector (code 2540.02.25P or 2540.12.25P) Pin 36-37 of the 37 pin multi-pole connector (code 2540.02.37P or 2540.12.37P) Output features: General characteristics Attention: The output connections are not protected against short-circuit. Please pay attention when wiring (avoid Pin 4 being connected to Pin 3 or Pin 1). Model Case I/O Connector PIN 1 voltage (connector used as Input) PIN 4 voltage diagnosis Node consumption (Outlets excluded) Outlets voltage Input voltage Maximum outlet current Maximum Input/Output Multiconnector max. Current Connections to manifold Maximum n. of moduls Protection degree Ambient temperature 2540.08T Reinforced technopolymer M8 connector 3 poles female (IEC 60947-5-2) By the user Green LED 7mA per each LED with 24 VDC signal +23,3 VDC (serial) /by the user (multipolar) Depend by the using 100 mA (serial) / 400 mA (multipolar) 8 per module 100 mA Direct connection to 25 poles connector 2 IP65 when assembled from -0° to +50° C Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 | 499
1106 Stránky | Platí do 06/2025 | Previous page | Další stránka
Vyberte si jazyk
Legální problémy
Výrobce je výhradně zodpovědný za obsah, cenu a detaily produktů a nabídek uvedených v katalozích. Technické a optické změny výrobce a chyby jsou vyhrazeny.
Formulář žádosti o speciální produkty
Služba nákupu ToolTeam®
Hledáte produkty, které jsou uvedeny v katalogu, ale nelze je zakoupit přímo online?Naše služba nákupu vám ráda zpracuje nezávaznou a individuální nabídku.
