Pneumax - Hauptkatalog Strana 481
Nabídka komerčních zákazníků **Nejlépe prodávané z Pneumax GmbH
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Solenoid valves manifold Series 2500 "OPTYMA-F" - Accessories Electric and electro-pneumatic cut off module Usage examples: EXAMPLE 1: Manifold of 12 monostable valves on which you want to interrupt signals 7-8 Assembly: - 6 monostable valves (not interruptible because before the module), - 1 additional power supply module, - 6 monostable valves. Please note: the first 2 monostable of these are interruptible by the module, while the following 4 will work correctly managed directly by the corresponding command signals. 2 3 4 5 6 7 8 9 10 11 12 EXAMPLE 2: Manifold of 12 monostable valves on which you want to interrupt signal 9 Assembly: - 8 monostable valves (not interruptible because before the module), - 1 additional power supply module, - 1 monostable valve (interruptible), - 1 closing plate mounted on a monostable base, - 3 monostable valves (work correctly managed directly by the corresponding command signals). 1 2 3 4 5 6 7 8 9 10 11 12 13 Please note: Each additional power supply module interrupts always 2 electrical signals. If you need to interrupt less than 2 signals you can: - assemble the valves to interrupt in the last positions of the manifold, so you don't need to worry about the interrupted exceeding signals; - use a bistable base and mount a monostable valve (for each signal less than the 2 standard); - use a monostable base and mount a closing plate (for each signal less than the 2 standard). E EXAMPLE 3: Manifold of 7 monostable e 3 bistable valves on which you want to interrupt signals 2-3 and 8-9. Assembly: - 1 monostable valve (not interruptible because before the module), - 1 additional power supply module, - 6 monostable valves. Please note: the first 2 monostable of these are interruptible by the module, while the following 4 will work correctly managed directly by the corresponding command signals. - 1 additional power supply module, - 3 bistable valves. Please note: the first bistable of these valves is interruptible by the module, while the following 2 will work correctly managed directly by the corresponding command signals. 1 2 3 4 5 6 7 8 9 11 13 10 12 Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distributiOn 1 1 | 461
1106 Stránky | Platí do 06/2025 | Previous page | Další stránka
Vyberte si jazyk
Legální problémy
Výrobce je výhradně zodpovědný za obsah, cenu a detaily produktů a nabídek uvedených v katalozích. Technické a optické změny výrobce a chyby jsou vyhrazeny.
Formulář žádosti o speciální produkty
Služba nákupu ToolTeam®
Hledáte produkty, které jsou uvedeny v katalogu, ale nelze je zakoupit přímo online?Naše služba nákupu vám ráda zpracuje nezávaznou a individuální nabídku.
