Pneumax - Hauptkatalog Strana 448
Nabídka komerčních zákazníků **Nejlépe prodávané z Pneumax GmbH
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Solenoid valves manifold Series 2200 "OPTYMA-S" - Accessories 8 Input/Output Module CORRESPONDENCE BETWEEN MULTI-POLE SIGNAL AND CONNECTOR PIN 13 PIN 12 PIN 11 PIN 10 PIN 9 PIN 8 PIN 7 PIN 6 PIN 5 PIN 4 PIN 3 PIN 2 PIN 1 PIN 18 PIN 17 PIN 19 PIN 25 PIN 24 PIN 23 PIN 22 PIN 21 PIN 20 PIN 19 PIN 18 PIN 17 PIN 16 PIN 15 PIN 14 1 - 22 = SIGNALS 23 - 24 = GND 25 = THROUGH LINE PIN 37 PIN 36 PIN 35 PIN 34 PIN 33 PIN 32 PIN 31 PIN 30 PIN 29 PIN 28 PIN 27 PIN 26 PIN 25 PIN 24 PIN 23 PIN 22 PIN 21 PIN 20 1 - 32 = SIGNALS 33 - 35 = GND 36 - 37 = THROUGH LINE 1 3 1 SUB-D TYPE 25 POLE MALE CONNECTOR PIN 16 PIN 15 PIN 14 PIN 13 PIN 12 PIN 11 PIN 10 PIN 9 PIN 8 PIN 7 PIN 6 PIN 5 PIN 4 PIN 3 PIN 2 PIN 1 SUB-D TYPE 37 POLE MALE CONNECTOR 4 PIN DESCRIPTION THROUGH 1 LINE 4 SIGNAL 3 GND Air distributiOn Connection modes: The I/O module changes it is operation depending on the way the manifold is controlled. There are two possible modes: In order to use the I/O module, the correct right hand endplate with 25 pole female outlet connector must be used. (Code 2240.03.25P). A) Control via multi-pole connection B) Control via fieldbus A) Control via multi-pole : M8 connector used as Input: M8 connector used as Output: Output voltage will the same as is applied at the multi-pole connector pin. The maximum output current depends upon the power unit used, but we recommend no more than 250mA. Attention: Voltage applied to each connector is passed to multi-pole connector pin. Attention: Since every cable has a degree of resistance, there will always be a voltage drop depending on the cable’s length, sectional area and the current. 3 1 9 1 2 3-4 5-6 7-8 4 10 11 12 13 PIN DESCRIPTION 1 THROUGH LINE 4 SIGNAL 3 GND Attention: Only one more I/O module can be added. Multi-pole connector pin 1 2 3-4 5-6 7-8 14 15 16 Module 1 9 10 11 12 13 17 18 19 20 21 37 poles Connector Attention: No more additions are possible Multi-pole connector pin 14 15 16 22 23 24 Module 1 Module 2 Attention : Optyma 32-S solenoid valve manifolds permit up to 22 electrical signals that are not used by manifolds to be made available: these signals can be managed by another manifold and / or by I/O modules. The I/O module will manage these unused signals. Connections that are not managing useful signals will remain unconnected. 1 2 3-4 5-6 7-8 22 Signals : 1 2 3-4 5-6 37 poles Connettor 7 8 9-10 11-12 13-14 18 19 20 21 23 24 25 26 27 10 11 12 13 15 16 17 18 19 17 20 21 22 28 14 15 16 22 9 Maximum 22 Signals Multi-pole connector pin Outlet signals from manifold Please note: this example considers a 37 pin multi-pole connector. The same configuration managed by a 25 pin multi-pole connector will stop at number 22 of multi-pole connector and at number 17 of the manifold. 22 16 1 | 428 Not Connected Module 1 Module 2 Attention: Signal Not connected GND Connected Through line Connected Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice
1106 Stránky | Platí do 06/2025 | Previous page | Další stránka
Vyberte si jazyk
Legální problémy
Výrobce je výhradně zodpovědný za obsah, cenu a detaily produktů a nabídek uvedených v katalozích. Technické a optické změny výrobce a chyby jsou vyhrazeny.
Formulář žádosti o speciální produkty
Služba nákupu ToolTeam®
Hledáte produkty, které jsou uvedeny v katalogu, ale nelze je zakoupit přímo online?Naše služba nákupu vám ráda zpracuje nezávaznou a individuální nabídku.
