Pneumax - Hauptkatalog Strana 107
Nabídka komerčních zákazníků **Nejlépe prodávané z Pneumax GmbH
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Spool valves and solenoid valves Series 888 Manifold layout Configuration Point to Point V22 5/2 valves P (point to point) _ _ P (point to point) V22 ... _ _ ... Nr. POSITIONS: VOLTAGE: SHORT CODE FUNCTION / CONNECTION : Nr. POSITIONS: VOLTAGE: SHORT CODE FUNCTION / CONNECTION : A= 02 positions B= 03 positions C= 04 positions D= 05 positions E= 06 positions F= 07 positions G= 08 positions H= 09 positions I= 10 positions M= 12 positions Q= 16 positions A= 12 V DC B= 24 V DC C= 24 V (50-60 Hz) D= 110 V (50-60 Hz) E= 230 V (50-60 Hz) Z= without coil G1= EV 3/2 SOL.-SPRING G1/8" N.O. G2= EV 3/2 SOL.-SPRING G1/4" N.O. H1= EV 3/2 SOL.-SPRING G1/8" N.C. H2= EV 3/2 SOL.-SPRING G1/4" N.C. A= 02 positions B= 03 positions C= 04 positions D= 05 positions E= 06 positions F= 07 positions G= 08 positions H= 09 positions I= 10 positions M= 12 positions Q= 16 positions A= 12 V DC B= 24 V DC C= 24 V (50-60 Hz) D= 110 V (50-60 Hz) E= 230 V (50-60 Hz) Z= without coil A1= S.V. 5/2 SOL.-SPRING G1/8" A2= S.V. 5/2 SOL.-SPRING G1/4" D1= S.V. 5/2 SOL.-SPRING G1/8" EXT. FEED. B1= S.V. 5/2 SOL.-SOL. G1/8" B2= S.V. 5/2 SOL.-SOL. G1/4" E1= S.V. 5/2 SOL.-SOL. G1/8" EXT. FEED. C1= S.V. 5/3 CC SOL.-SOL. G1/8" C2= S.V. 5/3 CC SOL.-SOL. G1/4" F1= S.V. 5/3 CC SOL.-SOL. G1/8" EXT. FEED. C3= S.V. 5/3 OC SOL.-SOL. G1/8" C4= S.V. 5/3 OC SOL.-SOL. G1/4" F3= S.V. 5/3 OC SOL.-SOL. G1/8" EXT. FEED. C5= S.V. 5/3 PC SOL.-SOL. G1/8" C6= S.V. 5/3 PC SOL.-SOL. G1/4" F5= S.V. 5/3 PC SOL.-SOL. G1/8" EXT. FEED. T3= VALVE SPACE PLUG L1= EV 3/2 SOL.-SPRING G1/8" N.O. EXT. FEED. M1= EV 3/2 SOL.-SPRING G1/8" N.C. EXT. FEED. N1= EV 3/2 SOL.-SOL. G1/8" N2= EV 3/2 SOL.-SOL. G1/4" P1= EV 3/2 SOL.-SOL. G1/8" EXT. FEEDING T4= VALVE SPACE PLUG 3/2 Manifold layout Configuration Multi-pole V22 LEFT ENDPLATES P2= 25 poles (max. 11 S.E.) P3= 37 poles (max. 16 S.E.) M (Multi-pole) __ _ _ ... SHORT CODE FUNCTION / CONNECTION : LEFT BOARD SIGNALS RIGHT BOARD SIGNALS C= 04 positions G= 08 positions M= 12 positions Q= 16 positions C= 04 positions G= 08 positions M= 12 positions Q= 16 positions 00= no board A1= S.V. 5/2 SOL.-SPRING G1/8" A2= S.V. 5/2 SOL.-SPRING G1/4" D1= S.V. 5/2 SOL.-SPRING G1/8" EXT. FEEDING B1= S.V. 5/2 SOL.-SOL. G1/8" B2= S.V. 5/2 SOL.-SOL. G1/4" E1= S.V. 5/2 SOL.-SOL. G1/8" EXT. FEEDING C1= S.V. 5/3 CC SOL.-SOL. G1/8" C2= S.V. 5/3 CC SOL.-SOL. G1/4" F1= S.V. 5/3 CC SOL.-SOL. G1/8" EXT. FEEDING C3= S.V. 5/3 OC SOL.-SOL. G1/8" C4= S.V. 5/3 OC SOL.-SOL. G1/4" F3= S.V. 5/3 OC SOL.-SOL. G1/8" EXT. FEEDING C5= S.V. 5/3 PC SOL.-SOL. G1/8" C6= S.V. 5/3 PC SOL.-SOL. G1/4" F5= S.V. 5/3 PC SOL.-SOL. G1/8" EXT. FEEDING T1= VALVE SPACE PLUG + Nr. 2 ELECTRICAL SPACE PLUGS Serial manifold layout (for the serial system node, see the Optyma-F Series) V22 S (Serial) __ _ __ A= None D1= 8IN DIGITAL MODULE M8 D2= 16IN DIGITAL MODULE D-SUB 25 P T1= 2IN ANALOG MODULE 0-5V T2= 2IN ANALOG MODULE 0-10V C1= 2IN ANALOG MODULE 0-20mA C1= 2IN ANALOG MODULE 4-20mA SERIAL NODE _ ... SHORT CODE FUNCTION / CONNECTION : INPUT MODULE C3= CANopen® 32 OUT D3= DeviceNet 32 OUT P3= PROFIBUS DP 32 OUT A3= EtherCAT® 32 OUT I3= EtherNet/IP 32 OUT N3= PROFINET IO RT/IRT 32 OUT L3= Powerlink 32 OUT M3= Modbus/TCP 32 OUT _ LEFT BOARD SIGNALS RIGHT BOARD SIGNALS C= 04 positions G= 08 positions M= 12 positions Q= 16 positions C= 04 positions G= 08 positions M= 12 positions Q= 16 positions 00= no board A1= S.V. 5/2 SOL.-SPRING G1/8" A2= S.V. 5/2 SOL.-SPRING G1/4" D1= S.V. 5/2 SOL.-SPRING G1/8" EXT. FEED. B1= S.V. 5/2 SOL.-SOL. G1/8" B2= S.V. 5/2 SOL.-SOL. G1/4" E1= S.V. 5/2 SOL.-SOL. G1/8" EXT. FEED. C1= S.V. 5/3 CC SOL.-SOL. G1/8" C2= S.V. 5/3 CC SOL.-SOL. G1/4" F1= S.V. 5/3 CC SOL.-SOL. G1/8" EXT. FEED. C3= S.V. 5/3 OC SOL.-SOL. G1/8" C4= S.V. 5/3 OC SOL.-SOL. G1/4" F3= S.V. 5/3 OC SOL.-SOL. G1/8" EXT. FEED. C5= S.V. 5/3 PC SOL.-SOL. G1/8" C6= S.V. 5/3 PC SOL.-SOL. G1/4" F5= S.V. 5/3 PC SOL.-SOL. G1/8" EXT. FEED. T1= VALVE SPACE PLUG + Nr. 2 ELECTRICAL SPACE PLUGS NOTE: When constructing the configuration, please consider that the maximum number of valves that can be mounted on the manifold is 16, regardless of the valve type. Any valve position presents two electrical connections: in case of use of monostable valves( A1-A2) it will be necessary to assemble a plug to protect the unused electrical connection. The correspondence between the electrical signal and its location on the manifold is showed in the following diagrams. Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 | 87 1 Air distributiOn 3/2 valves
1106 Stránky | Platí do 06/2025 | Previous page | Další stránka
Vyberte si jazyk
Legální problémy
Výrobce je výhradně zodpovědný za obsah, cenu a detaily produktů a nabídek uvedených v katalozích. Technické a optické změny výrobce a chyby jsou vyhrazeny.
Formulář žádosti o speciální produkty
Služba nákupu ToolTeam®
Hledáte produkty, které jsou uvedeny v katalogu, ale nelze je zakoupit přímo online?Naše služba nákupu vám ráda zpracuje nezávaznou a individuální nabídku.
