MUNK - Access Solutions 2023 Strana 359
Nabídka komerčních zákazníků **Produkty z katalogové stránky
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Shaft ladder GFRP Clear width 300 mm/400 mm Rectangular side-rails 58 x 25 mm Grooved rungs Various wall anchors available as accessories Number of rungs Approx. ladder length in m Outer width mm Clear width Ordering mm no. Outer width mm Clear width Ordering mm no. 4 1.12 350 300 64004 450 400 64104 5 1.40 350 300 64005 450 400 64105 6 1.68 350 300 64006 450 400 64106 7 1.96 350 300 64007 450 400 64107 8 2.24 350 300 64008 450 400 64108 9 2.52 350 300 64009 450 400 64109 10 2.80 350 300 64010 450 400 64110 11 3.08 350 300 64011 450 400 64111 12 3.36 350 300 64012 450 400 64112 13 3.64 350 300 64013 450 400 64113 14 3.92 350 300 64014 450 400 64114 15 4.20 350 300 64015 450 400 64115 Fig.: Order no. 64007 Note: Products with GFRP content are non-returnable, due to their sensitivity Country-specific regulations must be taken into account for fall protection In Germany, the Technical Regulations or Workplaces and German Social Accident Insurance (DGUV) regulations apply Shaft ladders with a fall height of more than 5 m need to be equipped with equipment to prevent falling, such as fall protection equipment or a tripod with fall arrester with a rescue function Safety railings are required with fall heights of more than 3 m in clarification plants (see DIN EN 12255-10 and DGUV Regulation 103-007) If there is a danger of falling into or drowning in liquid matter, then protection against falling is required regardless of the fall height Special regulations may apply in residential water management facilities and in landfill facilities 359 06
404 Stránky | Platí do 12/2023 | Previous page | Další stránka
Vyberte si jazyk
Legální problémy
Výrobce je výhradně zodpovědný za obsah, cenu a detaily produktů a nabídek uvedených v katalozích. Technické a optické změny výrobce a chyby jsou vyhrazeny.
Formulář žádosti o speciální produkty
Služba nákupu ToolTeam®
Hledáte produkty, které jsou uvedeny v katalogu, ale nelze je zakoupit přímo online?Naše služba nákupu vám ráda zpracuje nezávaznou a individuální nabídku.
