MUNK - Access Solutions 2023 Strana 334
Nabídka komerčních zákazníků **Produkty z katalogové stránky
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
min. 2000 mm to top edge back protection hoop min. 2000 mm up to top edge rung 06 2200–2500 mm up to bottom edge back protection hoop Head up to www.steigtechnik.de Figure in accordance with DIN EN ISO 14122-4:2016 Range of application Access to machinery and mechanical systems Gap at exit step must not be larger than 60–75 mm Step-on dimension: Distance from entry level to first rung 100–400 mm. The top edge of the Back protection is preferable to climbing protection uppermost rung must be at the same height as the as fall protection (combination is not permitted, walking surface of the exit point because back protection hinders the rescue of The clearances between the vertical ladder system persons) and the railing must not exceed 120 mm Irrespective of the climbing height: The need for an occupational medical examination The connection to the fall protection must be for suitability for working at height (e.g. G 41) established and released from a secured standing depends on the risk assessment (e.g. total climbing position. A secured standing position is, for height, type of fall protection) of the respective example, a platform with railing and secured vertical ladder system access Proof of the load-bearing capacity of the underlying surface must be provided for each construction project by a responsible stability expert Barrier (safety door) is always required If required by the access situation, vertical ladders with fall protection must be fitted with suitable protective devices (e.g. steel lockable door) to prevent unauthorised use For lateral bridging steps, the ladder sections must run at a higher level The overlap of the back protection must be at least 2,000 mm for multiple-flight ladders At unsecured exit points, railings attached to both sides of the vertical ladder or led into the exit level are required 334
404 Stránky | Platí do 12/2023 | Previous page | Další stránka
Vyberte si jazyk
Legální problémy
Výrobce je výhradně zodpovědný za obsah, cenu a detaily produktů a nabídek uvedených v katalozích. Technické a optické změny výrobce a chyby jsou vyhrazeny.
Formulář žádosti o speciální produkty
Služba nákupu ToolTeam®
Hledáte produkty, které jsou uvedeny v katalogu, ale nelze je zakoupit přímo online?Naše služba nákupu vám ráda zpracuje nezávaznou a individuální nabídku.
