fischer Installation Systems Main Catalog Strana 409

Nabídka komerčních zákazníků **
Strana 408fischer Installation Systems Main Catalog Strana 409
Zobrazit produkty
search
keyboard_arrow_up
/ 512

Produkty z katalogové stránky

keyboard_arrow_down
  • SW 10|Sechskant (2)
  • SW 13|Sechskant (2)
  • TX30|Innenstern TX (1)
keyboard_arrow_down
  • 90,00 (4)
  • 180,00 (1)
keyboard_arrow_down
  • Ja (5)
keyboard_arrow_down
  • M6 (1)
-49% Fischer Fischer UltraCut FBS II 6x50/5 US SW10 R 573423
573423
207,40 €
Bez dopravy
(2,07 € / Kus)
404,60 € Výrobcem doporučená malobchodní cena.
3 Variants
-49% Fischer Fischer UltraCut FBS II 6x85/25 P R 573431
573431
203,30 €
Bez dopravy
(2,03 € / Kus)
396,55 € Výrobcem doporučená malobchodní cena.
4 Variants
-49% Fischer Fischer UltraCut FBS II 6x85/25 US SW13 R 573428
573428
235,40 €
Bez dopravy
(2,35 € / Kus)
459,29 € Výrobcem doporučená malobchodní cena.
3 Variants
-49% Fischer Fischer UltraCut FBS II 6x55 M6 I 554066
554066
90,20 €
Bez dopravy
(0,90 € / Balíček)
175,45 € Výrobcem doporučená malobchodní cena.
4 Variants
-45% Fischer Fischer UltraCut FBS II 6x25 M8/19 546395
546395
46,10 €
Bez dopravy
(0,46 € / Kus)
83,89 € Výrobcem doporučená malobchodní cena.
5 Variants
Zobrazit všechny Fischer produkty
Concrete screw UltraCut FBS II 6 Plugs and anchors ■ Loads Concrete screw UltraCut FBS II 6 Permissible loads of a single anchor1) in normal concrete of strength class C20/25. For the design the complete current assessment ETA-15/0352 has to be considered. Material/ surface Minimum member thickness Maximum installation torque Non-cracked concrete Permissible tension (Nperm) and shear loads (Vperm); minimum spacing (smin) and edge distances (cmin) with reduced loads Permissible tension (Nperm) and shear loads (Vperm); minimum spacing (smin) and edge distances (cmin) with reduced loads hnom hmin Timp,max2) Nperm3) Vperm3) smin3) cmin3) Nperm3) Vperm3) smin3) cmin3) [mm] [mm] [Nm] [kN] [kN] [mm] [mm] [kN] [kN] [mm] [mm] gvz 40 80 450 1.2 4.3 35 35 3.8 4.3 35 35 gvz 45 90 450 1.7 4.3 35 35 4.8 4.3 35 35 gvz 50 90 450 1.9 4.3 35 35 5.7 4.3 35 35 gvz 55 100 450 2.4 6.3 35 35 6.4 6.3 35 35 Type FBS II 6 Screw-in depth Cracked concrete 1) Design according to EN 1992-4:2018 (for static resp. quasi-static loads). The partial safety factors for material resistance as regulated in the ETA as well as a partial safety factor for load actions of γL = 1.4 are considered. As a single anchor counts e.g. an anchor with a spacing s ≥ 3 x hef and an edge distance c ≥ 1.5 x hef. Accurate data see ETA. 2) Maximum allowable torque for installation with any tangential impact screw driver. Further technical data see ETA. 3) In the case of combinations of tension and shear loads, bending moments with reduced or minimum spacing and edge distances (anchor groups), the design must be carried out in accordance with the provisions of the complete ETA and the provisions of the EN 1992-4:2018. We recommend using our anchor design software C-FIX. Loads 11 Concrete screw UltraCut FBS II 6 Permissible loads for a single anchor1) for multiple use of redundant non-structural applications* in normal concrete C20/25. For the design the complete current assessment ETA - 18/0242 has to be considered. Material/ surface Minimum member thickness Maximum installation torque Non-cracked concrete Permissible tension (Nperm) and shear loads (Vperm); minimum spacing (smin) and edge distances (cmin) with reduced loads Permissible tension (Nperm) and shear loads (Vperm); minimum spacing (smin) and edge distances (cmin) with reduced loads hnom hmin Tinst,max2) Nperm3) Vperm3) smin3) cmin3) Nperm3) Vperm3) smin3) cmin3) [mm] [mm] [Nm] [kN] [kN] [mm] [mm] [kN] [kN] [mm] [mm] gvz 25 80 ≤5 0.7 1.8 35 35 1.4 2.3 35 35 gvz 30 80 ≤5 1.2 2.3 35 35 2.4 2.3 35 35 gvz 35 80 ≤5 1.7 4.3 35 35 3.1 4.3 35 35 gvz 40 80 ≤ 10 2.4 4.3 35 35 3.8 4.3 35 35 gvz 45 90 ≤ 10 2.9 4.3 35 35 4.8 4.3 35 35 gvz 50 90 ≤ 10 3.6 4.3 35 35 5.7 4.3 35 35 gvz 55 100 ≤ 10 4.0 6.3 35 35 6.4 6.3 35 35 Type FBS II 6 Screw-in depth Cracked concrete * In addition to the load table above, the following must be considered for multiple fastening of non-structural redundant systems: A multiple fixing (redundant system) according to EN 1992-4 and CEN/TR 17079 is defined by - at least 3 fixing points (per attached element) with at least one anchor at each fixing point and a permissible load per fixing point of 1.4 kN - or by at least 4 fixing points with at least one anchor each fixing point and a permissible load per fixing point of 2.1 kN - Additionally, it has to be proven that the stiffness of the attached element shall be large enough to ensure that in case of excessive slip or failure of a fastener the load on this fastener or fixing point can be transferred to neighbouring fixing points without significantly violating the requirements on the attached element in the serviceability and ultimate limit state. For further details see EN 1992-4 section 7.3 and CEN/TR 17079. 1) Design according to EN 1992-4:2018 (for static resp. quasi-static loads). The partial safety factors for material resistance as regulated in the ETA as well as a partial safety factor for load actions of γL = 1.4 are considered. γ Further technical information for installation see ETA. 3) In the case of combinations of tension and shear loads, bending moments with reduced or minimal edge and axial spacings (anchor groups), the design must be carried out in accordance with the provisions of the complete ETA and the provisions of the EN 1992-4:2018. 2) 409

512 Stránky | Platí do 12/2026 | |

PDF Download (54MB)
Uložit stránku jako PDF
Požádat o nabídku
(nezávazně)

Vyberte si jazyk

Legální problémy

Nabídka je zaměřena výhradně na firemní zákazníky, společnosti, veřejné instituce a živnostníky. Všechny ceny v katalozích jsou bez DPH, poštovného a příplatků, pokud li existují.
Výrobce je výhradně zodpovědný za obsah, cenu a detaily produktů a nabídek uvedených v katalozích. Technické a optické změny výrobce a chyby jsou vyhrazeny.

Formulář žádosti o speciální produkty

Personal-Quote Personal-Quote

Služba nákupu ToolTeam®

Hledáte produkty, které jsou uvedeny v katalogu, ale nelze je zakoupit přímo online?
Naše služba nákupu vám ráda zpracuje nezávaznou a individuální nabídku.


Vyplňte prosím všechna povinná pole (podtrženo červeně)
keyboard_arrow_down
Vyplňte prosím všechna povinná pole (podtrženo červeně)