fischer fixing-systems main-catalogue Strana 641
Nabídka komerčních zákazníků **Produkty z katalogové stránky
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Gas actuated fastening tool FGC 100 · Power tools Accessories Accessories for fixings Fuel cell FC 165 EWI plug TFD EWI nose FGC 100 - N EWI Magnetic nose piece supplement FGC 100 – N magnetic Length Technical details Item No. Contents [mm] Item Fuel cell FC 165 553416 165 For more than 1,100 fixings — EWI plug TFD 30 554928 30 To fix insulation material with a thickness of 50 mm, on soft concrete < C30/37 with DFN 40 504 EWI plug TFD 50 554929 50 Gvz with 5 µm coating thickness, for hard concrete ≥ C30/37 and steel, shaft diameter 3.0 mm, nail length 32 mm 504 EWI nose FGC 100-N EWI 554869 — For the use of fischer EWI plugs TFD 30 and TFD 50 1 Magnetic nose piece supplement FGC 100-N magnetic 553715 — For the use with metal washers 2 Metal washer FGC 100 554935 — It prevents fixture pull-over and is used with the magnetic nose piece supplement to fix wire mesh or membranes. 1,008 Cleaning kit FGC 100 553718 — 150 ml Cleaner, 100 ml Lubricating Oil and tool rubber sealing rings 1 Loads Standard nails DFN and high-performance nails DFNH Recommended loads¹) of a single nail in the respective building material as multiple use with at least 6 nails per attachment part. Building material Setting depth hef [mm] DFN DFNH Concrete C20/25²) ≥ 14 0.10 - Concrete C50/60²) Recommended tension load ¹) Frec [kN] ≥ 16 0.18 - ≥ 18 0.20 0.22 ≥ 20 0.20 0.50 ≥ 14 - 0.12 ≥ 17 - 0.18 ≥ 18 - 0.22 ≥ 20 0.50 - ≥ 25 0.68 - ≥ 27 0.80 - ≥ 29 0.95 - ≥ 14 0.10 - ≥ 16 0.16 - ≥ 18 0.19 - ≥ 20 0.19 - ≥8 - 0.96 Minimum member thickness hmin [mm] 60 60 Minimum edge distance cmin [mm] 70 70 Minimum member thickness hmin [mm] - 4 Minimum edge distance cmin [mm] - 14 Wood tfix [mm] 25 25 Metal sheet tfix [mm] 2.5 2.5 Solid sand-lime brick KS DIN EN 771-2 / KS 16 998 x 200 x 623 mm Solid brick Mz DIN EN 771-1 / Mz 20, DF Steel S235JR acc. to EN 10025-2 15 Member thickness and edge distance for concrete Member thickness and edge distance for steel Maximum fixture thickness ¹) Required safety factors are considered. Not for safety relevant single point fixings. All visible setting errors must be corrected. Use only in dry areas. To confirm the technical data, setting and load tests are recommended. ²) The load values in concrete are valid for tension and shear load. 641
684 Stránky | Platí do 12/2025 | Previous page | Další stránka
Vyberte si jazyk
Legální problémy
Výrobce je výhradně zodpovědný za obsah, cenu a detaily produktů a nabídek uvedených v katalozích. Technické a optické změny výrobce a chyby jsou vyhrazeny.
Formulář žádosti o speciální produkty
Služba nákupu ToolTeam®
Hledáte produkty, které jsou uvedeny v katalogu, ale nelze je zakoupit přímo online?Naše služba nákupu vám ráda zpracuje nezávaznou a individuální nabídku.
