fischer fixing-systems main-catalogue Strana 177
Nabídka komerčních zákazníků **Nejlépe prodávané z Fischer
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Concrete-concrete shear connector FCC · Chemical fixings Concrete-concrete shear connector FCC The approved system for building renovation 3 Upgrade of bridges Reinforcement of ceilings Applications Advantages · Bridge repairs · Increasing load capacity of bridges · Increasing loads of ceilings during conversion, for example · Reinforcement of foundations, piers, columns and walls · Renovation of car park ceilings following corrosion damage · Due to its geometry and ease of installation, FCC is the rapid and economic alternative compared to the conventional installation method with bent iron. · Dimensioning of the anchorage is possible thanks to the building approval. Thus, the system offers maximum security. · Variable anchoring depths allow for ideal adaptation to the load to be applied, and ensure an optimised installation time and use of materials. · Depending on site conditions, the FCC can be anchored, in compliance with the approval, with the injection mortars FIS SB or FIS EM Plus. · In conjunction with FIS EM Plus, FCC is also approved for use in diamond-drilled drill holes. Certificates Building materials Functioning Approved for: · Concrete C20/25 to C50/60, cracked and non-cracked · Fixing in old concrete B 25 to B 55 · The system consists of injection mortar (FIS SB or FIS EM Plus) and the concrete-concrete shear connector FCC. · The mortar is injected bubble-free from the drill hole base. · The mortar adheres the drill hole wall to the shear connector FCC. · The shear connector is set manually, by lightly rotating it until it reaches the drill hole base. · The tensile and shear forces arising in the joints between the old and new concrete are absorbed by the FCC-H and safely redirected. Versions · Zinc-plated concrete steel bar B500B 177
684 Stránky | Platí do 12/2025 | Previous page | Další stránka
Vyberte si jazyk
Legální problémy
Výrobce je výhradně zodpovědný za obsah, cenu a detaily produktů a nabídek uvedených v katalozích. Technické a optické změny výrobce a chyby jsou vyhrazeny.
Formulář žádosti o speciální produkty
Služba nákupu ToolTeam®
Hledáte produkty, které jsou uvedeny v katalogu, ale nelze je zakoupit přímo online?Naše služba nákupu vám ráda zpracuje nezávaznou a individuální nabídku.
