DELTAPLUS - Main Catalogue Strana 394
Nabídka komerčních zákazníků **Nejlépe prodávané z DELTA PLUS
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
376 Body protection TECHNICAL INFORMATION PROTECTIVE CLOTHING AGAINST COOL ENVIRONMENTS (1ৰ৳৯৴৷ This standard specifies the requirements and performance test methods for protective garments (vests, jackets, coats, trousers) against cool environments. These garments are for use in moderate low temperatures (-5°C and over) to protect against local body cooling. Not only for outdoor use such as in the construction industry; may also be used for indoor activities, such as in the food processing industry. These garments are not always necessarily made of air impermeable or watertight materials. Therefore, in this European standard, these requirements are optional. X : Class of heat resistance, Rct X : Class of air permeability, AP X : /cler of the garment (Optional) X : Class of resistance to water penetration WP (Optional) Water vapour resistance Ret Classe 1 2 3 4 M2 - Pa w Ret > 40 25 < Ret > 40 15 < Ret > 25 Ret < 15 ALASKA2 EN14058 3 3 0,285 m².K/W X Air speed 0.4 m/s Classe RESISTANCE TO WATER PENETRATION (WP) IN PASCAL: Measurement of the outer material and seams’ resistance to water penetration under a water pressure of (980+/-50) Pa/min. Divided into 4 levels (1 to 4) from the least impermeable to the most impermeable. Water penetration resistance WP Wearer standing still, 75 W/m² Insulation I cler M².K/W WATER VAPOUR RESISTANCE (Ret) IN (M².PA)/W : Measures the evaporative resistance, i.e. the product’s obstacle to the passage RIZDWHUYDSRXURUWKHEDUULHULWRↂHUVWRHYDSRUDWLRQRIWUDQVSLUDWLRQRQWKH surface of the skin. The higher a product’s water vapour resistance, the greater this product’s barrier to the passage of water vapour: A breathing product has a low water vapour resistance. Divided into 4 levels (from 1 to 4) from the least breathable to the most breathable. 3 m/s 8h 1h 8h 1h 0.170 21 9 24 15 0.265 13 0 19 7 0.310 10 -4 17 3 Classe 1 2 4 3 Specimen to be tested Material before treatment Material after each pre-treatment WP > 8 000 Pa - WP > 8 000 Pa WP > 13 000 Pa WP > 20 000 Pa Seams before pre-treatment WP > 8 000 Pa WP > 8 000 Pa WP > 13 000 Pa Seams after pre-treatment by cleaning - - - WP > 20 000 Pa TOWER TEST: (1৲৳৲ PROTECTIVE CLOTHING AGAINST RAIN 7KLVVWDQGDUGVSHFLↅHVWKHUHTXLUHPHQWVDQGWHVWPHWKRGVDSSOLFDEOHWRWKHPDWHULDOVDQG seams of protective clothing against foul weather (for example precipitation in the form of rain or snow), fog and ground humidity. y : Class of resistance to water penetration (1 to 4), Wp y : Class of water vapour resistance (1 to 4), Ret R : Water tower test on whole garment (optional) Wicking length on sleeves and lower hems Max 5 cm Wicking length on trouser hems Max 10 cm Wicking length on hood hems Max 4 cm Wet tricot area on manikin 0 cm2 FINNMARK2 EN343 KNEE PROTECTION 3 1 X (1ৰ৳৳৯৳ KNEE PROTECTION This European Standard provides the requirements and test methods for protective knee devices used by people that have kneel to carry out their work. This standard does not apply to the knee protection that are medical devices and are designed for sport. DEFINITIONS : THERMAL RESISTANCE (Rct) IN M².K/W: Measurement of the thermal insulation provided. Divided into 4 classes (from 1 to 4) from the least insulating to the most insulating. The higher the value, the greater the thermal insulation Type 1 Knee protection independent of other product and attached around the leg AIR PERMEABILITY (AP) IN MM/S: Type 2 Plastic foam or other padding inserted in the pockets of trousers or permanently attached to the trousers Determines the complex’s permeability to air. Divided into 3 classes (from 1 to 3) from the least airtight to the most airtight. Type 3 Devices that are not attached to the body but implemented during the movement of the user. They can be provided for each knee or both knees together Type 4 Protection of one or both knees, part of devices with additional functions, such as helping to stand or kneel. The knees protection can be worn on the body or independently RESULTANT EFFECTIVE THERMAL INSULATION: Measured on moving dummy (/cler) . 7KHWKHUPDOLQVXODWLRQFRHↃFLHQWH[SUHVVHGLQPt.:LVXVHGWRGHWHUPLQH the optimum usage temperature of the garment in relation to the individual’s activity and his exposure time. Thermal insulation is measured with undergarments of type: - (B) for ensembles (Undershirt with long sleeves, long underpants, socks, bootee + thermojacket, thermopants, knitted gloves, balaclava) - (R) for garments (Undershirt with long sleeves, long underpants, socks, bootees, jacket, trousers, shirt, knitted gloves, balaclava) - (C) provided by the manufacturer KNEE PROTECTION Level 0 .QHHSURWHFWRUVDUHVXSSRVHGWREHDGDSWHGWRↆDWↆRRUVDQGQRUHVLVWDQFHWR penetration is required Level 1 .QHHSURWHFWRUVDUHVXSSRVHGWREHVXLWDEOHIRUↆDWↆRRUVDQGUHVLVWDQFHWRSHQHWUDtion under a force of at least 100 (+/-5) N is required Level 2 .QHHSURWHFWRUVDUHVXSSRVHGWREHVXLWDEOHIRUGLↃFXOWFRQGLWLRQVDQGUHVLVWDQFHWR penetration under a force of at least 250 (+/-5) N is required Delta Plus provides protection at work from head to toe for both women and men
408 Stránky | Platí do 07/2023 | Previous page | Další stránka
Vyberte si jazyk
Legální problémy
Výrobce je výhradně zodpovědný za obsah, cenu a detaily produktů a nabídek uvedených v katalozích. Technické a optické změny výrobce a chyby jsou vyhrazeny.
Formulář žádosti o speciální produkty
Služba nákupu ToolTeam®
Hledáte produkty, které jsou uvedeny v katalogu, ale nelze je zakoupit přímo online?Naše služba nákupu vám ráda zpracuje nezávaznou a individuální nabídku.
