CELO main catalog Strana 117
Nabídka komerčních zákazníků **Produkty z katalogové stránky
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
CELO ResiTHERM® 37 technical data ResiTHERM® 37S Installation parameters ResiTHERM® 37/120 ResiTHERM® 37/160 ResiTHERM® 37/200 Anchor length Ld [mm] 125 245 285 325 7KLFNQHVVRILQVXODWLRQPDWHULDO LQFOH[WHUQDOSODVWHU hD [mm] 0 601) - 120 1201) - 160 1601) - 200 Anchor Ø dnom [mm] 37 Drill hole Ø d0 [mm] 39 - 40 Drill hole depth h1 ͡ [mm] 130 Anchorage depth hnom [mm] 125 ± 102) [mm] M12 hVPLQPD[ [mm] 35 - 80 223) Connecting thread Screw insertion depth of M12 threaded stud 7KLFNQHVVRIͤ[WXUH tͤ[͠ [mm] RIFOHDUDQFHKROHLQͤ[WXUH df ͡ [mm] Required volume of ResiFIX VY per ResiTHERM® 37 ,QVWDOODWLRQWRUTXHIRUPRXQWLQJWKHͤ[WXUH 13 [ml] Tinst͠ ca. 140 [Nm] 20 ResiTHERM® 37 may be cut up to 40 mm if needed. ResiTHERM® 37/120 M12: If thickness of insulation material is 60 mm, set 20 mm deeper. 2) Minimum anchorage depth of 115 mm is possible (see ETA assessment) 3) When using a threaded stud with L=70 mm. Otherwise a longer threaded stud or a longer metric screw can be used. 1) Loads and displacements/deflections ResiTHERM®37: approved system with injection system ResiFIX VY SF Building material System Thickness of insulation material [mm] Permissible tension load Hollow brick T1.0-240 HLZ 12 (Format 12 DF) Hollow brick T10-300 HLZ 6 (Format 10 DF) Aerated concrete AAC2-0,352) Aerated concrete AAC4-0,552) Single fastening Single fastening Single fastening Single fastening all all all all Permissible pressure load Hollow brick T1.0-240 HLZ 12 (Format 12 DF) Hollow brick T10-300 HLZ 6 (Format 10 DF) Single fastening Single fastening all all Permissible shear load Single fastening Hollow brick T1.0-240 HLZ 12 (Format 12 DF) Double fastening3) Single fastening Hollow brick T10-300 HLZ 6 (Format 10 DF) Double fastening3) 0 120 160 200 0 120 160 200 0 120 160 200 0 120 160 200 * Movement of ResiTHERM® 37 in load direction at permissible load. Recommended loads include the partial safety factor on action of ɶF = 1,4. Not part of the ETA-assessment. 3) Spacing of 77 mm (standard awning console). 4) Ǝv0 ,QLWLDOGHIOHFWLRQƎY͜= long-term deflection 1) 2) Application of ResiTHERM® 37 in solid building materials is possible. Contact CELO for details. 116 Recommended loads1) Deflection at recommended load* Nper [kN] ɷN0ͬɷEь [mm] 1,71 0,86 1,21 2,12 0,60/ 1,30 0,60/ 1,20 0,14/ 0,28 0,32/ 0,64 Fper [kN] ɷF0ͬɷ&ь[mm] 1,71 0,86 0,60/ 1,30 0,60/ 1,20 Vper [kN] ɷv0ͬɷǀь [mm] 4) 0,86 0,34 0,34 0,26 0,51 0,43 0,34 0,41 0,43 0,26 0,26 0,17 0,17 0,11 0,11 0,09 0,20/ 0,30 2,00/ 4,10 2,10/ 4,30 3,40/ 6,70 0,60/ 1,20 1,60/ 3,20 0,70/ 1,40 1,40/ 2,90 0,00/ 0,10 1,30/ 2,60 1,70/ 2,50 2,00/ 4,00 0,10/ 0,20 0,20/ 0,30 0,20/ 0,30 0,30/ 0,50
316 Stránky | Platí do 03/2023 | Previous page | Další stránka
Vyberte si jazyk
Legální problémy
Výrobce je výhradně zodpovědný za obsah, cenu a detaily produktů a nabídek uvedených v katalozích. Technické a optické změny výrobce a chyby jsou vyhrazeny.
Formulář žádosti o speciální produkty
Služba nákupu ToolTeam®
Hledáte produkty, které jsou uvedeny v katalogu, ale nelze je zakoupit přímo online?Naše služba nákupu vám ráda zpracuje nezávaznou a individuální nabídku.